Comparison of non-invasive blood pressure monitoring using modified arterial applanation tonometry with intra-arterial measurement
pmid: 28105538
Comparison of non-invasive blood pressure monitoring using modified arterial applanation tonometry with intra-arterial measurement
Intermittent non-invasive blood pressure measurement with tourniquets is slow, can cause nerve and skin damage, and interferes with other measurements. Invasive measurement cannot be safely used in all conditions. Modified arterial tonometry may be an alternative for fast and continuous measurement. Our aim was to compare arterial tonometry sensor (BPro®) with invasive blood pressure measurement to clarify whether it could be utilized in the postoperative setting. 28 patients who underwent elective surgery requiring arterial cannulation were analyzed. Patients were monitored post-operatively for 2 h with standard invasive monitoring and with a study device comprising an arterial tonometry sensor (BPro®) added with a three-dimensional accelerometer to investigate the potential impact of movement. Recordings were collected electronically. The results revealed inaccurate readings in method comparison between the devices based on recommendations by Association for the Advancement of Medical Instrumentation (AAMI). On a Bland-Altman plot, the bias and precision between these two methods was 19.8 ± 16.7 (Limits of agreement - 20.1 to 59.6) mmHg, Spearman correlation coefficient r = 0.61. For diastolic pressure, the difference was 4.8 ± 7.7 (LoA - 14.1 to 23.6) mmHg (r = 0.72), and for mean arterial pressure it was 11.18 ± 11.1 (LoA - 12.1 to 34.2) mmHg (r = 0.642). Our study revealed inaccurate agreement (AAMI) between the two methods when measuring systolic and mean blood pressures during post-operative care. The readings for diastolic pressures were inside the limits recommended by AAMI. Movement increased the failure rate significantly (p < 0.001). Thus, arterial tonometry is not an appropriate replacement for invasive blood pressure measurement in these patients.
- Tampere University Finland
- Tampere University Hospital Finland
- Tampere University of Technology Finland
Adult, Aged, 80 and over, Male, Critical Care, Manometry, Acceleration, Reproducibility of Results, Blood Pressure, Blood Pressure Determination, Signal Processing, Computer-Assisted, Middle Aged, Blood Pressure Monitors, Radial Artery, Humans, Arterial Pressure, Female, Postoperative Period, Aged, Monitoring, Physiologic
Adult, Aged, 80 and over, Male, Critical Care, Manometry, Acceleration, Reproducibility of Results, Blood Pressure, Blood Pressure Determination, Signal Processing, Computer-Assisted, Middle Aged, Blood Pressure Monitors, Radial Artery, Humans, Arterial Pressure, Female, Postoperative Period, Aged, Monitoring, Physiologic
8 Research products, page 1 of 1
- 2020IsAmongTopNSimilarDocuments
- 2020IsAmongTopNSimilarDocuments
- 2021IsAmongTopNSimilarDocuments
- 2013IsAmongTopNSimilarDocuments
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).17 popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.Top 10% influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).Average impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.Top 10%