Improved Polymer Hemocompatibility for Blood-Contacting Applications via S-Nitrosoglutathione Impregnation
Improved Polymer Hemocompatibility for Blood-Contacting Applications via S-Nitrosoglutathione Impregnation
Blood-contacting medical devices (BCMDs) are inevitably challenged by thrombi formation, leading to occlusion of flow and device failure. Ideal BCMDs seek to mimic the intrinsic antithrombotic properties of the human vasculature to locally prevent thrombotic complications, negating the need for systemic anticoagulation. An emerging category of BCMD technology utilizes nitric oxide (NO) as a hemocompatible agent, as the vasculature's endothelial layer naturally releases NO to inhibit platelet activation and consumption. In this paper, we report for the first time the novel impregnation of S-nitrosoglutathione (GSNO) into polymeric poly(vinyl chloride) (PVC) tubing via an optimized solvent-swelling method. Material testing revealed an optimized GSNO-PVC material that had adequate GSNO loading to achieve NO flux values within the physiological endothelial NO flux range for a 4 h period. Through in vitro hemocompatibility testing, the optimized material was deemed nonhemolytic (hemolytic index <2%) and capable of reducing platelet activation, suggesting that the material is suitable for contact with whole blood. Furthermore, an in vivo 4 h extracorporeal circulation (ECC) rabbit thrombogenicity model confirmed the blood biocompatibility of the optimized GSNO-PVC. Platelet count remained near 100% for the novel GSNO-impregnated PVC loops (1 h, 91.08 ± 6.27%; 2 h, 95.68 ± 0.61%; 3 h, 97.56 ± 8.59%; 4 h, 95.11 ± 8.30%). In contrast, unmodified PVC ECC loops occluded shortly after the 2 h time point and viable platelet counts quickly diminished (1 h, 85.67 ± 12.62%; 2 h, 54.46 ± 10.53%; 3 h, n/a; 4 h, n/a). The blood clots for GSNO-PVC loops (190.73 ± 72.46 mg) compared to those of unmodified PVC loops (866.50 ± 197.98 mg) were significantly smaller (p < 0.01). The results presented in this paper recommend further investigation in long-term animal models and suggest that GSNO-PVC has the potential to serve as an alternative to systemic anticoagulation in BCMD applications.
- University of Georgia Georgia
- University of Georgia United States
- UNIVERSITY OF GEORGIA
- University of Georgia Press United States
Male, Extracorporeal Circulation, Polymers, Surface Properties, Swine, Thrombosis, Nitric Oxide, Platelet Activation, Hemolysis, Materials Testing, Models, Animal, S-Nitrosoglutathione, Animals, Rabbits, Polyvinyl Chloride, Blood Coagulation
Male, Extracorporeal Circulation, Polymers, Surface Properties, Swine, Thrombosis, Nitric Oxide, Platelet Activation, Hemolysis, Materials Testing, Models, Animal, S-Nitrosoglutathione, Animals, Rabbits, Polyvinyl Chloride, Blood Coagulation
9 Research products, page 1 of 1
- 2005IsAmongTopNSimilarDocuments
- 1998IsAmongTopNSimilarDocuments
- 1998IsAmongTopNSimilarDocuments
- 2005IsAmongTopNSimilarDocuments
- 2022IsAmongTopNSimilarDocuments
- 2001IsAmongTopNSimilarDocuments
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).14 popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.Top 10% influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).Average impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.Top 10%