image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao IEEE Transactions on...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
IEEE Transactions on Nuclear Science
Article . 2002 . Peer-reviewed
License: IEEE Copyright
Data sources: Crossref
https://doi.org/10.1109/nssmic...
Article . 2002 . Peer-reviewed
Data sources: Crossref
versions View all 2 versions

Correction of the respiratory motion of the heart by tracking of the center of mass of thresholded projections: a simulation study using the dynamic MCAT phantom

Authors: P.P. Bruyant; M.A. King; P.H. Pretorius;

Correction of the respiratory motion of the heart by tracking of the center of mass of thresholded projections: a simulation study using the dynamic MCAT phantom

Abstract

During normal breathing, heart motion is about 15 mm along the body axis in humans. We propose a method to track and to correct this motion after a list-mode acquisition which involves the recording of a signal proportional to respiratory volume. We use the dynamic MCAT (DMCAT) chest phantom to simulate 24 temporal frames regularly spaced during the respiratory cycle, for 60 projection angles over 360/spl deg/. A 15-mm respiratory translation motion is simulated for the heart, liver and spleen. Thresholding of projections is used to reduce the influence of static activity on calculation of the axial center-of-mass (aCOM). Variation in the impact of attenuation as a function of projections and noise in the low-count projections rebinned from list-mode acquisitions is seen to limit ones ability to track respiratory motion using the aCOM. By including the recording of a signal proportional to the relative respiratory volume with the list-mode acquisition counts from different respiratory cycles can be combined to produce projections with common respiratory volumes. We have determined that the aCOMs determined from summing these common-volume based projections over the anterior to left-anterior oblique projection angles can be used to track respiratory motion as a function of the volume signal. Using this information on the variation of the aCOM as a function of the volume signal, the entire list-mode acquisition can then be rebinned into a projection set which is corrected for respiratory motion. After motion tracking, the mean absolute difference between the true motion curve and the aCOM curve is 0.10 cm for noisy studies. After correction no heart motion is visible on a cine display of projections. The polar map of myocardial MIBI uptake after motion correction is closer to that obtained when no respiratory motion is present than without correction.

  • BIP!
    Impact byBIP!
    citations
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    53
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
citations
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
53
Top 10%
Top 10%
Top 10%