Powered by OpenAIRE graph
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Biophysical Journalarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Biophysical Journal
Article
License: Elsevier Non-Commercial
Data sources: UnpayWall
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Biophysical Journal
Article . 2011
License: Elsevier Non-Commercial
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Biophysical Journal
Article . 2011 . Peer-reviewed
License: Elsevier Non-Commercial
Data sources: Crossref
versions View all 3 versions

Intramolecular Cav1.1 Chimeras Reveal the Molecular Mechanism Determining the Characteristic Gating Behaviour of the Skeletal Muscle Calcium Channel

Authors: Tuluc, Petronel; Grabner, Manfred; Flucher, Bernhard E.;

Intramolecular Cav1.1 Chimeras Reveal the Molecular Mechanism Determining the Characteristic Gating Behaviour of the Skeletal Muscle Calcium Channel

Abstract

The Ca2+ channel CaV1.1 is the voltage sensor of skeletal muscle excitation-contraction coupling. The classical skeletal muscle CaV1.1 isoform has poor voltage sensitivity and conducts a small, slowly activating Ca2+ current. In contrast, a splice variant lacking exon 29 (α1S-ΔE29) (Tuluc et al.,2009) has an 8-fold higher current amplitude, fast activation-kinetics, and a 30mV left-shifted voltage-dependence of activation. Therefore, the extracellular loop in repeat IV (IVS3-IVS4) mainly coded by exon 29 is a critical determinant of the characteristic gating properties of CaV1.1. Here we used intramolecular chimeras between repeats I and IV to characterize the structural basis of the gating properties of CaV1.1.Inserting exon 29 (alone or in combination with IVS3) into the corresponding region of repeat I was ineffective. However, in combination with the voltage sensor (IVS4) it fully restored α1S-like amplitude and voltage-sensitivity to α1S-ΔE29. Interestingly, all three chimeras exhibit faster activation kinetics. Secondary structure predictions showed that the long IVS3-IVS4 loop contains a beta-sheet while the short loop forms a coil. Point mutations in exon 29 which abolish the beta-sheet fully mimic the effects of deleting exon 29 regarding the kinetic properties and increase the current amplitude by 3-fold and left-shift the voltage dependence by −15mV. Together with previous findings (Nakai et al., 1994) our data suggest that the S3-S4 loop of the first repeat determines activation kinetics, while the corresponding loop plus voltage sensor in the fourth repeat with its unique secondary structure dictate the voltage-dependence, amplitude, and kinetics of skeletal muscle Ca2+ currents.Grants: PT (MFI-2007-417), BEF (FWF-P20059-B05).

Keywords

Biophysics

  • BIP!
    Impact byBIP!
    citations
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
citations
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
hybrid