Cataract Surgery with Foldable Single Piece IOLs in Congenital Cataract-Microcornea Syndrome
Cataract Surgery with Foldable Single Piece IOLs in Congenital Cataract-Microcornea Syndrome
Objective: To present the visual outcomes and intraocular lens (IOLs) stability after cataract surgery with foldable single piece IOLs in a patient with congenital cataract-microcornea syndrome (CCMC). Case presentation: A 28-year-old woman presented with bilateral microcornea and posterior polar cataract. Her uncorrected (UDVA) and corrected (CDVA) distance visual acuities were 20/100, 20/160 and 20/80, 20/80, respectively. The horizontal cornea diameter was 9.0 mm in both eyes. Anterior chamber angle assessment (ACAA) with Scheie classification showed grade 3 on the superior, inferior, and temporal site and grade 2 on the nasal site in both eyes. On ultrasound biomicroscopy (UBM), the anterior chamber depths were 2.35 mm. OD and 2.41 mm. OS. The axial lengths were 23.28 mm., OD and 22.50 mm. OS with the A-scan ultrasound biometry. The IOLs power calculation with SRK/T formulas was +25.00 diopter OD and +22.50 diopter OS (A-constant 118.4). Phacoemulsification was performed on both eyes. After lens aspiration, ruptured posterior capsule, a common complication occurred. Then anterior vitrectomy was performed. A foldable single piece IOLs without haptic trimming was implanted in the sulcus in each eye. CDVA was 20/63 equally in both eyes. The intraocular pressure was 12 and 14 mmHg. ACAA showed grade 2 and no pigment dispersion. The IOLs had no tilt or decentration. UBM showed the IOLs were in the proper position and were not rubbing the iris. Conclusion: The foldable single piece IOLs without haptic trimming in the sulcus were safely implanted in both eyes with microcornea in CCMC.
posterior polar cataract, (Siriraj Med J 2017;69: 388-390), intraocular lens, R, Medicine, Microcornea, Microcornea; posterior polar cataract; intraocular lens
posterior polar cataract, (Siriraj Med J 2017;69: 388-390), intraocular lens, R, Medicine, Microcornea, Microcornea; posterior polar cataract; intraocular lens
5 Research products, page 1 of 1
- 2007IsAmongTopNSimilarDocuments
- 2006IsAmongTopNSimilarDocuments
- 2021IsAmongTopNSimilarDocuments
- 2022IsAmongTopNSimilarDocuments
- 2014IsAmongTopNSimilarDocuments
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).0 popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.Average influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).Average impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.Average